  (On-line UPS) PS/3-Series UPS | Eco-Series UPS | Max-Series UPS
 
     
 
  ECO-SERIES UPS (ONLINE)
  Catalogue
 
   
   
FEATURES
  • True On-Line Double Conversion type UPS System
  • IGBT technology design
  • Pure Sinewave output
  • Bypass provided
  • Compact and well engineered architecture
  • Neutral isolation design
  • High input power factor >0.97
  • Full bridge inverter
  • Overload and output short circuit protection
  • Wide input tolerance range
  • Smooth and silent operation
  • Fast correction rate for line and load regulation
  • Compatible with the intelligent data protection package
  • Easy to install, use and maintain
  • Superior performance to price analysis
 
       
 
  SPECIFICATIONS
  Model Capacity UPSU01
1KVA(1000VA)
(36V DC)
UPSU03
3KVA(3000VA)
(96V DC)
 
  Input
 
Voltage
Frequency
Power factor
150V-275V  
50±5%  
>0.95 conforms to EN 605552
 
 
 
 
  Output
 
 
 
 
Voltage
Phase
Regulation
Frequency
Power factor
Waveform Distortion
Crest factor
Overload capacity
Inverter Efficiency
220 VAC ± 3%  
1 phase 2W + G  
±1% at linear load  
50Hz±0.5%  
0.7  
Pure sinewave less than 3% at full load
3:1  
>105% for 10 sec. >110% for 200 msec.
>93%  
  Battery Built - in
Rating
Recharge time
3x12V-7AH 8x12V-7AH
4 -8 hrs. 90% after fully discharge
  Transfer Time
Bypass to UPS
UPS to Bypass
No break  
<2ms  
 
  Indicator
 
 
Multi-function
LED Display
LCD Display
 
Line, Inverter, Bypass, Fault, Battery Load Level
 
Output Frequency/Voltage, Input Frequency/Voltage
Load percentage, Battery percentage (Optional)
 
  Audible Alarm
 
1. AC Failure
2. Battery low
3. UPS Fault
Sounds every 4 seconds after line fails
Sounds every second when approaches level
Continuous alarm
 
 
 
 
  Protection
 
 
 
Over/Under voltage at I/P
 
Short circuit & Overload
 
 
 
Yes
 
 
The UPS shuts down and will not transfer to the bypass when short circuit occurs on the output of the unit. After rectification of short circuit, the UPS operates normally again. At short condition, the Fault LED lights as a warning.
Lighting:Yes Surge:Yes
 
  Environment
 
Temperature
Humidity
Audible Noise
0°C to 40°C
0 to 95% at non condensing
<45 dB at 1 metre
  Connection Interface Port RS-232 connector
  Interface
  Software
Power Status, UPS Shutdown, Moniter UPS Status, UPS Self Test
  Dimensions HxWxD (mm)
220x145x405 330x195x455